MFC1000 – Standard – Diode Rectifier

Logo oficial de TWERD ENERGO-PLUS en versión blanca para variadores de frecuencia y equipos de potencia

TWERD Energo-Plus Drives
MFC1000 - Standard Diode Rectifier

For General Purposes and Petroleum Applications

MFC1000 Standard | Diode Rectifier

Robust, reliable, cost-effective, and high-efficiency variable frequency drive technology, based on a state-of-the-art 6-pulse uncontrolled diode bridge rectifier. Designed for maximum durability in demanding industrial environments, this equipment combines a simplified power stage with advanced Direct Torque Control with Space Vector Modulation (DTC-SVM) algorithms. It delivers excellent starting torque performance, immediate dynamic response, and superior cost-effectiveness for the protection and control of induction and permanent magnet motors.

Standard Diode Rectifier
Maximum Reliability | Optimized Investment

SectorAplicacionBeneficios
Oil & GasProgressive Cavity Pumps (PCP)Precise speed control and continuous operation under demanding environmental conditions.
Water and SanitationCentrifugal pumps, drinking water and wastewater pumping stations, and constant-pressure systems.Significant energy savings through flow control without valve throttling.
HVAC Systems / BuildingsForced- and induced-draft fans, exhaust fans, and chilled-water or condenser-water pumps.Reduced electricity consumption and less mechanical wear during start-stop cycles.
General Industry and ManufacturingConveyor belts, mixers, agitators, extruders, and blowers.Constant or variable torque with rapid dynamic response to load variations.
Agricultural SectorAeration pumps, irrigation systems, and deep-well pumping systems.Reliable operation with minimal maintenance in remote or rural areas.

Advantages of Using Standar 6-Pulse Diode Drives

MFC1000 - Standard
for Progressive Cavity Pumping (PCP)

Sistema de cabezal de rotación para bombeo de cavidad progresiva (BCP) en pozo petrolero con variador de frecuencia TWERD
  • Configuration and monitoring of BCP parameters
  • Torque protections
  • Configuration and protection via pressure sensors
  • Backspin control (with and without power)

MFC1000
for Electric Submersible Pumping (ESP)

Cabezal de pozo petrolero con árbol de navidad en instalación para sistema de levantamiento artificial por bombeo electrosumergible BES
  • ESP Parameter Configuration and Monitoring
  • Backspin Protection
  • Pressure Sensor Monitoring and Control
  • Pump Protection
Tablero de control industrial con variador de frecuencia TWERD instalado junto a un cabezal BCP en pozo petrolero

Key Features

MFC1000 Standard
Diode Rectifier
Progressive Cavity Pump (PCP) Firmware

The standard MFC1000 variable speed drive is a 6-pulse technology converter featuring diode-bridge rectification; it is designed to deliver solid, robust, and highly reliable performance in demanding industrial applications while serving as a highly cost-effective solution.

It utilizes vector-controlled torque technology to meet requirements for high starting torque, precise speed control, and excellent dynamic torque response.

Suitable for a wide range of applications, this series offers integrated PID control, an intuitive user interface, flexible I/O expansion, compatibility with multiple Fieldbus communication modules, comprehensive electrical protection, high resilience to harsh environmental conditions, and easy maintenance.

For oil industry applications, it features specialized software for Progressive Cavity Pumping (PCP) systems, designed to meet the sector’s mechanical and electrical demands and ensure greater operational reliability:

 

Intelligent Torque Adjustment

Integrated protection for the pumping unit, ensuring operational optimization.

Micro-cut management

Avoid production losses caused by power supply interruptions by maintaining well operations.

Automatic restart

Minimizes downtime and allows production to resume without on-site operator intervention.

Backspin Management

Prevents mechanical damage to the pump unit.

Filtro armónico pasivo trifásico para reducción de distorsión armónica THDi en variadores de frecuencia.
Diagrama de flujo de sistema con red eléctrica, filtro armónico pasivo, variador de frecuencia MFC1000 y motor eléctrico industrial.

Harmonic Filter for Variable Frequency Drives with 6-Pulse Diode Rectifier.

Passive harmonic filter specially designed for 6-pulse static power converters, such as power converters, variable frequency drives, three-phase rectifiers, battery chargers, HVAC systems, etc.

Technical Specifications: MFC 1000 Standard for BCP Artificial Lift

Input

Power
150 HP
Voltage
3-phase AC 380V-480V (-15%-+10%)
Input frequency
60 Hz ±5%
Rectifier technology
Diode bridge
Rectifier switching frequency
2.5 kHz
DPF displacement factor = Cos phi
cos1 (fundamental)
Electrical micro-cuts
500ms
Current THD
requires the use of an external harmonic filter
Output
Output Frequency
0,0...400 Hz U/f operation mode
0,0120 Hz - Vector operation mode
Output Current
180 A
Output Voltage
0 a Un
Efficiency
98% at rated load
Control System
Control Method
Linear, Quadratic U/f Scalar
Sensorless DTC-SVM
Vector-based DTC-SVM with rotor position sensor
Switching frequency
1 a 8 kHz
Modulator
SVPWM
Speed ​​reference type
Analog Inputs
Control Panel
Potentiometer
PID controller
RS232 or RS485 communication bus
Other possibilities.
Overload capacity

Instantaneous overload torque 0–60 Hz, 60 seconds
150%
Starting Torque (Between 0 and 0.5 Hz) 3 seconds
200%
Environmental conditions


Operating ambient temperature
-10°C a +50°C
Ambient storage temperature
-25 Ca +55°C
Humidity
5% a 95%
Altitude
1,000 m.a.s.l.
Protections

Motor Protection
Stall motor
Motor Overload (thermal model)
Output current limiting
Current imbalance
Voltage imbalance
Motor overtemperature (PT100, PTC)
Speed ​​Limit
Torque Limitation
Speed ​​discrepancy
Ground fault
Drive Protections
IGBT Overload
Phase loss
Low input voltage
High input voltage
High-voltage DC bus voltage limit,
Low-voltage DC bus
IGBT temperature
 Power supply failure
Ground fault
Loss of analog input signal
Loss of speed reference
Emergency stop
Hardware



Digital inputs
10 digital inputs DI1...DI10
Digital Outputs 0/(15...24)V, Rin ≥ 3k Ω.
The possibility of obtaining up to 30 digital inputs on expansion cards.

Digital Outputs
6 salidas digitales a relé K1... K6 - breaking capacity: 250V/1A AC, 24V/1A DC. .
The possibility of obtaining up to 11 digital outputs on expansion cards.

Analog Inputs
5 entradas analógicas A10: 
5 entradas analógicas AI0: voltage mode 0(2)... 10V, Rin ≥ 200k
Al1, A12, A13, A14: voltage mode 0(2)... 10V, Rin ≥ 100kΩ;
 current mode 0(4)...20mA, Rin = 250
Analog Outputs
2 salidas analógicas A01, A02:
Voltage mode 0(2)...10 V
Current mode 0(4)...20 mA
Communication

Standard port
USB port
RS485 port x 2
Ethernet
Protocolos estandar
Modbus-RTU
Ethernet (Modbus TCP)

Control Panel


Type
Removable
Length
Up to 10 meters (optional)
Status LEDs
LED RUN. Motor running.
LED READY: Awaiting march order
LED READY: En espera de orden de march

Display LCD
LCD screen
10-key keypad for drive control and configuration (start, stop, and reset); parameter backup.
Stop and reset, parameter backup
Application



Oil and gas application
Progressive Cavity Pump (PCP) Application
Autonomy of operation without tension at maximum load
In the event of a supply voltage interruption, the drive continues to operate using the kinetic energy of the rotating motor by internally switching the control mode from speed control to zero torque, thereby maximizing the unit's ride-through time during power loss—up to 500 ms.
Backspin Control
Yes (during a normal stop and in the absence of voltage).

Data Logger
Memory storage capacity for up to 20 operational variables, with an adjustable sampling frequency (in seconds) covering a 3-month period. Event logging with date and time using an RTC (Real-Time Clock). Data download via USB port 1)
PCP Application Software
Rod string torque control and protection (regulation torque and adjustable trip torque) 2) Software-based speed and torque control via signals (suction and discharge pressure, suction and discharge temperature via 4-20mA signals) 3) Speed ​​control via surface signals (wellhead pressures—tubing and annulus—and wellhead temperature) 4) Rod string backspin braking control.

Operational functions




Number of attempts and restart times
Up to 6 user-programmable restarts, with timing adjustments via the "Total trial time" and "Delay time" parameters. Selection of faults to be reset using the automatic reset function.

Programmable acceleration time
Programmable 0 to 600 seconds (internal VFD); programmable up to 6,000 seconds via HMI application.

Programmable deceleration time
Programmable internal VFD (0 to 600 seconds); programmable 0 to 6000 seconds via HMI application.
Starter type
Linear and S-type acceleration ramp. Acceleration ramp for programmable flakspin control independent of that used in normal operation.
Load torque type
Constant to Variable
Stop type
Linear and S-curve deceleration ramps; independently configurable ramp for emergency stops; programmable braking management function; DC injection braking (DC Hold function); flux braking.

Special Features
Internal PLC
Ability to control an external process without the need for an external PLC; 48 universal function blocks; 43 functions (including simple logic and arithmetic operations); an 8-state sequencer block; and 2 multiplexers with 8 inputs.

PID controller
Selection of reference signal source and feedback signal source, option to change error control signal polarity, Sleep function, output value limiting.

Additional panel functions
Definition of user values ​​for direct process observation, selection of unit of measurement, scale, and data source. LCD contrast adjustment.
Regulations
Product conformity
IEC/EN 50178:2003
IEC/EN 61800-5-1:2007 +
IEC/EN 61800-3:2008
ISO9001
Esta web utiliza cookies propias y de terceros para su correcto funcionamiento y para fines analíticos. Contiene enlaces a sitios web de terceros con políticas de privacidad ajenas que podrás aceptar o no cuando accedas a ellos. Al hacer clic en el botón Aceptar, acepta el uso de estas tecnologías y el procesamiento de tus datos para estos propósitos.
Privacidad