Av Araguaney QTA El Refran
Lecheria-Anzoategui, Venezuela
J-503572507
Lunes a Viernes: 8AM - 7PM
Fin de semana: 8AM - 12PM
Robust, reliable, cost-effective, and high-efficiency variable frequency drive technology, based on a state-of-the-art 6-pulse uncontrolled diode bridge rectifier. Designed for maximum durability in demanding industrial environments, this equipment combines a simplified power stage with advanced Direct Torque Control with Space Vector Modulation (DTC-SVM) algorithms. It delivers excellent starting torque performance, immediate dynamic response, and superior cost-effectiveness for the protection and control of induction and permanent magnet motors.
| Sector | Aplicacion | Beneficios |
|---|---|---|
| Oil & Gas | Progressive Cavity Pumps (PCP) | Precise speed control and continuous operation under demanding environmental conditions. |
| Water and Sanitation | Centrifugal pumps, drinking water and wastewater pumping stations, and constant-pressure systems. | Significant energy savings through flow control without valve throttling. |
| HVAC Systems / Buildings | Forced- and induced-draft fans, exhaust fans, and chilled-water or condenser-water pumps. | Reduced electricity consumption and less mechanical wear during start-stop cycles. |
| General Industry and Manufacturing | Conveyor belts, mixers, agitators, extruders, and blowers. | Constant or variable torque with rapid dynamic response to load variations. |
| Agricultural Sector | Aeration pumps, irrigation systems, and deep-well pumping systems. | Reliable operation with minimal maintenance in remote or rural areas. |
MFC1000 – Standard version with diode rectifier
The MFC1000 variable frequency drive is equipped with a conventional diode rectifier on the supply side.
Power flow in this system is unidirectional: electrical energy drawn from the mains is supplied directly to the motor.
During motor braking (generator mode), kinetic energy is transferred back to the drive’s DC bus.
Excess energy can be dissipated as heat via an external braking resistor, using an integrated braking unit.
Note: The braking unit is optional and must be specified when ordering.
Power supply: 3 x 500 V or 3 x 690 V, 45 .. 60 Hz
Output: 0 .. 400 Hz, 3 x 400 V, 3 x 500 V or 3 x 690 V
Output Current :
Overload:1.5 in for 60 seconds every 10 minutes
Modes of Operation:
Includes 4 PID controllers with a “SLEEP” function.
Built-in incremental encoder interface (5 V line driver)
Braking Types
Analog Inputs: 5
Analog Outputs: 2 to 12 with expansion module
Digital inputs: 10 to 40 with expansion module
Relay outputs: 6 (up to 11 with expansion module)
Built-in communication interfaces:
IP Protection: IP21
External Dimensions: 301.94x800x300 mm
Weight: From 82 kg +/- 10 kg, depending on the model and configuration.

The standard MFC1000 variable speed drive is a 6-pulse technology converter featuring diode-bridge rectification; it is designed to deliver solid, robust, and highly reliable performance in demanding industrial applications while serving as a highly cost-effective solution.
It utilizes vector-controlled torque technology to meet requirements for high starting torque, precise speed control, and excellent dynamic torque response.
Suitable for a wide range of applications, this series offers integrated PID control, an intuitive user interface, flexible I/O expansion, compatibility with multiple Fieldbus communication modules, comprehensive electrical protection, high resilience to harsh environmental conditions, and easy maintenance.
For oil industry applications, it features specialized software for Progressive Cavity Pumping (PCP) systems, designed to meet the sector’s mechanical and electrical demands and ensure greater operational reliability:
Integrated protection for the pumping unit, ensuring operational optimization.
Avoid production losses caused by power supply interruptions by maintaining well operations.
Minimizes downtime and allows production to resume without on-site operator intervention.
Prevents mechanical damage to the pump unit.
Passive harmonic filter specially designed for 6-pulse static power converters, such as power converters, variable frequency drives, three-phase rectifiers, battery chargers, HVAC systems, etc.
Input | Power | 150 HP |
Voltage | 3-phase AC 380V-480V (-15%-+10%) | |
Input frequency | 60 Hz ±5% | |
Rectifier technology | Diode bridge | |
Rectifier switching frequency | 2.5 kHz | |
DPF displacement factor = Cos phi | cos1 (fundamental) | |
Electrical micro-cuts | 500ms | |
Current THD | requires the use of an external harmonic filter | |
Output | Output Frequency | 0,0...400 Hz U/f operation mode 0,0120 Hz - Vector operation mode |
Output Current | 180 A | |
Output Voltage | 0 a Un | |
Efficiency | 98% at rated load | |
Control System | Control Method | Linear, Quadratic U/f Scalar Sensorless DTC-SVM Vector-based DTC-SVM with rotor position sensor |
Switching frequency | 1 a 8 kHz | |
Modulator | SVPWM | |
Speed reference type | Analog Inputs Control Panel Potentiometer PID controller RS232 or RS485 communication bus Other possibilities. | |
Overload capacity | Instantaneous overload torque 0–60 Hz, 60 seconds | 150% |
Starting Torque (Between 0 and 0.5 Hz) 3 seconds | 200% | |
Environmental conditions | Operating ambient temperature | -10°C a +50°C |
Ambient storage temperature | -25 Ca +55°C | |
Humidity | 5% a 95% | |
Altitude | 1,000 m.a.s.l. | |
Protections | Motor Protection | Stall motor Motor Overload (thermal model) Output current limiting Current imbalance Voltage imbalance Motor overtemperature (PT100, PTC) Speed Limit Torque Limitation Speed discrepancy Ground fault |
Drive Protections | IGBT Overload Phase loss Low input voltage High input voltage High-voltage DC bus voltage limit, Low-voltage DC bus IGBT temperature Power supply failure Ground fault Loss of analog input signal Loss of speed reference Emergency stop | |
Hardware | Digital inputs | 10 digital inputs DI1...DI10 Digital Outputs 0/(15...24)V, Rin ≥ 3k Ω. The possibility of obtaining up to 30 digital inputs on expansion cards. |
Digital Outputs | 6 salidas digitales a relé K1... K6 - breaking capacity: 250V/1A AC, 24V/1A DC. . The possibility of obtaining up to 11 digital outputs on expansion cards. | |
Analog Inputs | 5 entradas analógicas A10: 5 entradas analógicas AI0: voltage mode 0(2)... 10V, Rin ≥ 200k Al1, A12, A13, A14: voltage mode 0(2)... 10V, Rin ≥ 100kΩ; current mode 0(4)...20mA, Rin = 250 | |
Analog Outputs | 2 salidas analógicas A01, A02: Voltage mode 0(2)...10 V Current mode 0(4)...20 mA | |
Communication | Standard port | USB port RS485 port x 2 Ethernet |
Protocolos estandar | Modbus-RTU Ethernet (Modbus TCP) | |
Control Panel | Type | Removable |
Length | Up to 10 meters (optional) | |
Status LEDs | LED RUN. Motor running. LED READY: Awaiting march order LED READY: En espera de orden de march | |
Display LCD | LCD screen 10-key keypad for drive control and configuration (start, stop, and reset); parameter backup. Stop and reset, parameter backup | |
Application | Oil and gas application | Progressive Cavity Pump (PCP) Application |
Autonomy of operation without tension at maximum load | In the event of a supply voltage interruption, the drive continues to operate using the kinetic energy of the rotating motor by internally switching the control mode from speed control to zero torque, thereby maximizing the unit's ride-through time during power loss—up to 500 ms. | |
Backspin Control | Yes (during a normal stop and in the absence of voltage). | |
Data Logger | Memory storage capacity for up to 20 operational variables, with an adjustable sampling frequency (in seconds) covering a 3-month period. Event logging with date and time using an RTC (Real-Time Clock). Data download via USB port 1) | |
PCP Application Software | Rod string torque control and protection (regulation torque and adjustable trip torque) 2) Software-based speed and torque control via signals (suction and discharge pressure, suction and discharge temperature via 4-20mA signals) 3) Speed control via surface signals (wellhead pressures—tubing and annulus—and wellhead temperature) 4) Rod string backspin braking control. | |
Operational functions | Number of attempts and restart times | Up to 6 user-programmable restarts, with timing adjustments via the "Total trial time" and "Delay time" parameters. Selection of faults to be reset using the automatic reset function. |
Programmable acceleration time | Programmable 0 to 600 seconds (internal VFD); programmable up to 6,000 seconds via HMI application. | |
Programmable deceleration time | Programmable internal VFD (0 to 600 seconds); programmable 0 to 6000 seconds via HMI application. | |
Starter type | Linear and S-type acceleration ramp. Acceleration ramp for programmable flakspin control independent of that used in normal operation. | |
Load torque type | Constant to Variable | |
Stop type | Linear and S-curve deceleration ramps; independently configurable ramp for emergency stops; programmable braking management function; DC injection braking (DC Hold function); flux braking. | |
Special Features | Internal PLC | Ability to control an external process without the need for an external PLC; 48 universal function blocks; 43 functions (including simple logic and arithmetic operations); an 8-state sequencer block; and 2 multiplexers with 8 inputs. |
Funciones Especiales | PID controller | Selection of reference signal source and feedback signal source, option to change error control signal polarity, Sleep function, output value limiting. |
Additional panel functions | Definition of user values for direct process observation, selection of unit of measurement, scale, and data source. LCD contrast adjustment. | |
Regulations | Product conformity | IEC/EN 50178:2003 IEC/EN 61800-5-1:2007 + IEC/EN 61800-3:2008 ISO9001 |